Engineered wood flooring
Engineered wood flooring can be floated, glued down or secret nailed. The right method depends on the subfloor, the board and the instructions supplied with the product.
Before you start
- The room, subfloor and flooring must be ready. See Is the room ready?, Subfloor requirements and Inspect your flooring.
- Plan the layout. Boards usually run along the longest wall or towards the main light source. Avoid very narrow strips at the edges.
- Leave expansion gaps around the whole floor. See Expansion gaps.
Floating
The boards are joined to each other but not fixed to the subfloor. They sit on an underlay.
- On concrete or screed, use an underlay with a built-in damp-proof membrane, or lay a separate membrane first, with joints overlapped and taped.
- Click boards lock together without glue. Tongue and groove boards are glued in the joint with a suitable wood adhesive, as the instructions direct.
- Stagger end joints so they do not line up. A common guide is at least 500 mm apart, or at least twice the board width.
- Do not fix anything heavy through or on top of the floor, such as kitchen units or islands.
- Large or long floors may need expansion joints. Check the instructions for the maximum floating area.
Glued down
Each board is fully bonded to the subfloor. This gives a solid feel underfoot and suits underfloor heating well.
- The subfloor must be clean, dry, flat and primed if the adhesive maker says so.
- Use a flexible wood flooring adhesive suitable for the board and the subfloor. Spread it with the trowel size the adhesive maker specifies, to get full contact under each board.
- Check contact by lifting a board now and then. Wipe any adhesive off the surface straight away.
- Keep foot traffic off the floor until the adhesive has set, as stated by the adhesive maker.
Secret nailed
Boards are nailed through the tongue into a timber or plywood subfloor, so the fixings are hidden.
- Only for subfloors that can hold a nail, such as plywood or timber boards. Not for concrete or screed.
- As a general guide, fix at 200 mm to 300 mm intervals along each board, at least 50 mm from the board ends, driven at about 45 degrees through the tongue.
- Use the nailer and fixings the instructions specify. If the instructions give a different spacing, follow them.
- Not every engineered board is suitable for nailing. Check the minimum thickness in the instructions.
Always use the fitting method, adhesive and underlay recommended in the instructions supplied with your flooring. Using a different method can affect any warranty.
Most wood floor problems are traced back to site conditions, moisture or installation, not the product. Following this guidance and the instructions supplied with your flooring is the best way to avoid them.
This is general guidance. Always follow the instructions supplied with your flooring. If in doubt, ask your supplier or a qualified fitter before you start.
Back to all guidance